DE-11 Digitales Taschenmultimeter
4000 Counts
29 Ranges of Measurement
Auto Range
- LCD Display:3 3/4 Digits LCD With 4000 Counts
- Range:Automatic
- Sampling Reading Rate:Approx. 3 Times/ Sec.
-
Low
Battery:
Symbol Display
- Auto Power Off:In 15 Minutes Approx.
- Battery:Li-ion Cell Battery CR2032 x1
- Battery Life:Approx. 200 Hours At DCV
- Safety standard:IEC 61010-1 CAT. II 600V Pollution Degree 2
Measurement Ranges:
(23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)
Measurement |
Range |
Resolution |
Accuracy |
Input Resistance |
Remarks |
DE-11 |
|||||
(ACV) |
4V |
0.001V |
2.3%+10 |
approx. 11MΩ |
*Accuracy in the case of sine wave. *Frequency range 40~500Hz |
40V |
0.01V |
approx. 10MΩ |
|||
400V |
0.1V |
2.3%+5 |
|||
600V |
1V |
||||
(DCV) |
400mV |
0.1mV |
0.7%+3 |
≥100MΩ |
──── |
4V |
0.001V |
1.3%+3 |
approx. 11MΩ |
||
40V |
0.01V |
approx. 10MΩ |
|||
400V |
0.1V |
||||
600V |
1V |
||||
(Resistance) |
400Ω |
0.1Ω |
2%+5 |
──── |
*Openvoltage:approx.0.4V *The measuring current changes in accordance with the resistance measured. |
4kΩ |
0.001kΩ |
||||
40kΩ |
0.01kΩ |
||||
400kΩ |
0.1kΩ |
||||
4MΩ |
0.001MΩ |
5%+5 |
|||
40MΩ |
0.01MΩ |
10%+5 |
|||
(DIODE) |
4V |
0.001V |
10%+5 |
──── |
Open voltage:Approx.1.5V |
(BUZZER) |
400Ω |
0.1Ω |
──── |
──── |
*Buzzer turns on less than 60±20Ω *Open voltage:Approx. 0.4V |
(CAP) |
4nF |
0.001nF |
5%+25 |
──── |
Accuracy is subject to zero set by pressing relative key before forwarding measurement. |
40nF |
0.01 nF |
5%+10 |
|||
400nF |
0.1nF |
||||
4μF |
0.001μF |
||||
40μF |
0.01μF |
10%+15 |
|||
200μF |
0.1μF |
||||
Hz |
9.999Hz |
0.001Hz |
0.7%+5 |
──── |
*Accuracy in the case of sine wave. 9.999Hz~9.999kHz:10Vrms min 99.99kHz:40Vrms min |
99.99Hz |
0.01Hz |
||||
999.9Hz |
0.1Hz |
||||
9.999kHz |
0.001kHz |
||||
99.99kHz |
0.01kHz |
||||
DUTY |
0.1~99% |
0.1% |
──── |
──── |
*About input sensitivity and frequency characteristic: (Square wave DUTY 50% input) 2.5V 0 to peak input:≧1kHz 6V 0 to peak input:≧10kHz 40V 0 to peak input:≧70kHz |
TEMP./Humidity:
- Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
- Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)
Dimension
& Weight:
- 110(L)x56(W)x11.5(H)mm
- Approx.99.3 (Including Battery & Leather Case)
Accessories:
- Instruction Manual x 1
- CR2032 Li-ion Cell (installed) x1
- Test Lead (black + red attached with Meter) x 1
- Leather Case x1
- Super Slim & Light Design
- Auto Range
- Auto Power Off Selection
- 29 Ranges of Measurement
- Capacitance Measurement
- Hz / Duty Measurement
- Relative Measurement
- Data Hold
- Leather Case Holder
- Test Leads Stored Inside-Easy To Carry